Ulasan Umum adalah merupakan salah satu peringkat penting dalam pembangunan Malaysian Standard (MS). Jabatan Standard Malaysia (JSM) menjemput semua pihak untuk mengemukakan maklumbalas/komen terhadap draf MS, selaras dengan Artikel 4 dan Annex 3 Perjanjian WTO/TBT. Ini termasuklah Malaysian Standard (MS) yang baharu, semakan semula, pindaan dan penarikan balik MS sedia ada. Kesemua komen akan dipertimbangkan oleh Jawatankuasa Pembangunan Standard yang berkaitan di bawah seliaan JSM.

Untuk maklumat lanjut mengenai ulasan umum, sila hubungi:
Pasukan Ulasan Umum
Bahagian Standardisasi
Jabatan Standard Malaysia
CYBERJAYA
E-mel: pc[at]jsm[dot]gov[dot]my
-
Bil Tajuk Muat Turun 1 Ulasan Umum untuk Standard Dalam Pembangunan PDF -
15 MEI 2026 - 15 JULAI 2026
DALAM PEMBANGUNAAN
15 MEI 2026 - 15 JULAI 2026
No.
Tajuk DMS
Skop
Butiran NSC 06 - MECHANICAL ENGINEERING
1. DMS 2804
Non-destructive testing —
Qualification and certification of personnel
for NDT in civil engineering (NDT-CE)This document specifies the requirements for the qualification and certification of personnel who perform non-destructive testing in the civil engineering (NDT-CE) sector focusing on concrete structures using the following methods. Within the context of NDT-CE, all listed below are referred to as NDT-CE methods:
a) acoustic emission testing;
b) carbonation test;
c) chloride test;
d) computed tomography;
e) cover meter;
f) dynamic tests;
g) flat jack test;
h) ground penetrating radar;
i) impact echo;
j) leak testing;
k) parallel seismic test;
l) penetration resistance test;
m) potential mapping;
n) pull off test;
o) pull out test;
p) radiographic testing;
q) rebound hammer;
r) resistivity measurement;
s) strain gauge testing;
t) thermographic testing;
u) ultrasonic pulse echo;
v) ultrasonic pulse velocity; and
w) visual testing.
The system specified in this document is also applicable to other NDT-CE methods, provided a comprehensive scheme of certification exists. Additionally, the NDT-CE method must be covered by international, regional, or national standards, or it must be demonstrated to be effective to the satisfaction of the certification body.
NOTE 1 This document specifies requirements for third-party conformity assessment schemes, which involve independent organizations organisations evaluating and certifying the qualifications of personnel in NDT-CE. These requirements do not directly apply to conformity assessments conducted by second parties (such as clients evaluating suppliers) or first parties (such as self-assessments by the organisation). However, relevant parts of this document can be referenced or utilized in such arrangements to ensure a level of consistency and reliability in the qualification and certification process.
Email: pc[at]jsm[dot]gov[dot]my
-
15 JUN 2026 - 14 OGOS 2026
DALAM PEMBANGUNAN
15 JUN 2026 - 14 OGOS 2026
No.
Tajuk of DMS
Skop
Butiran NSC 01 - AGRICULTURE
1. DMS 1836
Hydrated lime and slurry lime for use in potable water supply — SpecificationThis document specifies the requirements for unplasticized poly(vinyl chloride) (PVC-U) solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and piping systems intended to be used for non-pressure underground drainage and sewerage under the following conditions:
a) buried in ground outside the building structure (application area code "U"); and
b) both buried in ground, within the building structure and outside the building (application area code "UD").
NOTE The intended use is reflected in the marking of products by "U" or "UD".
It also specifies the test parameters for the test methods referred to in this document. This document covers a range of nominal sizes, a range of pipes and fittings series and a range of stiffness classes and gives recommendations concerning colours.
NOTE It is the responsibility of the purchaser or specifier to make the appropriate selection from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
It is applicable to PVC-U pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended for buried piping systems for non-pressure underground drainage and sewerage.
Email: pc[at]jsm[dot]gov[dot]my
-
15 JULAI 2026 - 15 OGOS 2026
DALAM PEMBANGUNAN
15 JULAI 2026 - 15 OGOS 2026
No.
Tajuk DMS
Skop
Butiran NSC 19 - ELECTRICAL AND ELECTRONICS EQUIPMENTS AND ACCESORIES
1. DMS IEC 62305-2:2024
Protection against lightning – Part 2: Risk management (IEC 62305-2:2024, IDT)
Provides risk management of a structure due to lightning flashes to earth.
Its purpose is to provide a procedure for the evaluation of such a risk. Once an upper tolerable limit for the risk has been selected, this procedure provides a means for the selection of appropriate protection measures to be adopted to reduce the risk to or below the tolerable limit.
Risk management also includes the evaluation of frequency of damage of internal systems caused by surges due to lightning flashes to earth.
Once an upper tolerable limit for the frequency of damage has been selected, this procedure provides a means for the selection of
appropriate protection measures to be adopted to reduce the frequency of damage to or below the tolerable limit.
Email: pc[at]jsm[dot]gov[dot]my
-
15 MEI 2026 - 15 JULAI 2026
-
Bil Tajuk Muat Turun 1 Ulasan Umum untuk Standard yang Ditarik Balik Tanpa Gantian Isi Borang PDF -
15 JULY 2026 - 14 SEPTEMBER 2026
15 JULY 2026 - 14 SEPTEMBER 2026
No.
MS Number
Title
NSC Approval Date
Justification for Withdrawal
NSC 19 - ELECTRICAL AND ELECTRONICS EQUIPMENT AND ACCESORIES
1
MS 2085:2008
Domestic and similar electronic equipment interconnection requirements - Peritelevision connector (BS EN 50049-1:1998)
10 February 2026
MS 2085:2008 which is technically identical to BS EN 50049-1:1998 has become outdated following the withdrawal of the international standard by British Standards Institution (BSI) in 2014. As a result, the standard is no longer applied by industry in Malaysia.
Therefore, NSC 19 has agreed to withdraw MS 2085:2008 without replacement.2 MS IEC 60107-1:2008 Methods of measurement on receivers for television broadcast transmissions - Part 1: General considerations - Measurements at radio and video frequencies (IEC 60107-1:1997, IDT) 10 February 2026 MS IEC 60107-1:2008 which is identical to IEC 60107-1:1997 is technologically obsolete and no longer aligned with current industry requirements.
Therefore, NSC 19 has agreed to withdraw MS IEC 60107-1:2008 without replacement.3 MS IEC 60598-2-9:2001 Luminaires - Part 2: Particular requirements section nine - Photo and film luminaires (Non-professional) (IEC 60598-2-9:1987, AMD. 1:1993, IDT) 9 February 2026 MS IEC 60598-2-9:2001 which is identical to IEC 60598-2-9:1987+AMD. 1:1993 has become outdated following the withdrawal of the international standard by the International Electrotechnical Commission (IEC) in October 2019. As a result, the standard is no longer applied by industry in Malaysia.
Therefore, NSC 19 has agreed to withdraw MS IEC 60598-2-9:2001 without replacement.4 MS IEC 60598-2-24:2006 Luminaires – Part 2-24: Particular requirements – Luminaires with limited surface temperatures (IEC 60598-2-24:1997, IDT) 9 February 2026 MS IEC 60598-2-24:2006 which is identical to IEC 60598-2-24:1997 has become outdated following the withdrawal of the international standard by the International Electrotechnical Commission (IEC) in June 2013. As a result, the standard is no longer applied by industry in Malaysia.
Therefore, NSC 19 has agreed to withdraw MS IEC 60598-2-24:2006 without replacement.
5 MS IEC 60966-3-2:2007 Radio frequency and coaxial cable assemblies - Part 3-2: Detail specification for semi-flexible coaxial cable assemblies for GSM use (0,8 GHz - 1 GHz) (First Revision) (IEC 60966-3-2:2003, IDT) 10 February 2026 MS IEC 60966-3-2:2007 which is identical to IEC 60966-3-2:2003 is technologically obsolete and no longer aligned with current industry requirements.
Therefore, NSC 19 has agreed to withdraw MS IEC 60966-3-2:2007 without replacement. -
1 AUGUST 2026 - 30 SEPTEMBER 2026
1 AUGUST 2026 - 30 SEPTEMBER 2026
No.
MS Number
Title
NSC Approval Date
Justification for Withdrawal
NSC 04 - BUILDING AND CIVIL ENGINEERING WORKS
1
MS ISO 6240:2011
Performance standards in building – Contents and presentation (ISO 6240:1980, IDT)
12 November 2025
MS ISO 6240:2011, which is identical to ISO 6240:1980, has become outdated following the withdrawal of the international standard by the International Organization for Standardization (ISO) in October 2016. NSC 04 has agreed to withdraw MS ISO 6240:2011 without replacement, as it is obsolete and no longer aligned with current industry practices in Malaysia.
2 MS ISO 6241:2011
Performance standards in building – Principles for their preparation and factors to be considered (ISO 6241:1984, IDT)
12 November 2025
MS ISO 6241:2011, which is identical to ISO 6241:1984, has become outdated following the withdrawal of the international standard by the International Organization for Standardization (ISO) in October 2016. NSC 04 has agreed to withdraw MS ISO 6241:2011 without replacement, as it is obsolete and no longer aligned with current industry practices in Malaysia
-
15 JULY 2026 - 14 SEPTEMBER 2026